Home Products & Solutions Suction & Fluid Management
VacSax® FluidGuard Flexi — Now in Ghana

Safe. Smart.
Sustainable Suction.

TEPG is the exclusive Ghana distributor of VacSax® FluidGuard Flexi — a CE and UKCA-marked disposable liner suction system engineered for safety, infection control and environmental sustainability in endoscopy and surgical environments.

About VacSax® FluidGuard Flexi

Modern Suction Management for Clinical Environments

The VacSax FluidGuard Flexi system uses a disposable liner insert within a reusable canister — employing vacuum action to draw fluids from the surgical or endoscopy site safely into a sealed, antimicrobial liner.

The range comprises 1 litre, 2 litre and 3 litre configurations, with both standard and pre-gelled liner options — suitable for endoscopy units, operating theatres and other clinical environments across Ghana.

CE Marked
UKCA Marked
Now Available in Ghana
VacSax FluidGuard Flexi System
Exclusive
Ghana
Distributor

Safe

Engineered with several safety features to ensure optimal protection and minimise risk. Single patient port system prevents cross-contamination. Hydrophobic bacterial shut-off filter provides complete overflow protection.

Smart

The only system where, when in use, all external surfaces of the liner, canister and vacuum tubing have antimicrobial properties via Bacticlear® technology. Semi-rigid liner stands upright even when removed and full of fluid.

Sustainable

Designed with less plastic and efficient packaging to lower waste and reduce CO₂ emissions. The reusable canister model significantly reduces single-use plastic waste compared to fully disposable systems.

Liner & Canister Range

Available Products

1 litre, 2 litre and 3 litre configurations — standard and pre-gelled liners — with compatible antimicrobial canisters in V Mount, European Parallel and American Parallel configurations.

Disposable Liners
Part No. Description Qty/Box
VFS-1011000 ml FluidGuard Flexi Liner24 pcs
VFS-2012000 ml FluidGuard Flexi Liner24 pcs
VFS-3013000 ml FluidGuard Flexi Liner24 pcs
VFS-1111000 ml FluidGuard Flexi Liner Pre-Gelled22 pcs
VFS-2112000 ml FluidGuard Flexi Liner Pre-Gelled20 pcs
VFS-3113000 ml FluidGuard Flexi Liner Pre-Gelled20 pcs
Reusable Canisters
Part No. Description Qty
3833-1001L Antimicrobial V Mount Canister w/bypass1 pc
3833-2101L Antimicrobial Parallel European w/bypass1 pc
3833-2121L Antimicrobial Parallel American w/bypass1 pc
3833-0552L Antimicrobial V Mount Canister w/bypass1 pc
3833-1652L Antimicrobial Parallel European w/bypass1 pc
3833-0582L Antimicrobial Parallel American w/bypass1 pc
3833-0413L Antimicrobial V Mount Canister w/bypass1 pc
3833-0453L Antimicrobial Parallel European w/bypass1 pc
3833-0423L Antimicrobial Parallel American w/bypass1 pc

VacSax Liner Features

All VacSax liners carry the CE and UKCA mark and conform to relevant standards and regulations.

Folded for Easy Storage
Unique patented design folded for ease and space saving.
Conical Design
Simple set up, easy removal and safe handling.
Semi-Rigid — Stands Upright
Remains upright when removed from the canister, even when full of fluid.
Moulded Volume Markings
External markings give an approximate indication of suctioned contents.
Tapered Vacuum Port
Secure connection to the vacuum source for reliable suction performance.
Hydrophobic Bacterial Filter
Porous plug filter provides complete overflow protection against bacterial contamination.
How FluidGuard Works

Simple Setup. Safe Disposal.

The system uses a disposable liner inside a reusable canister. Vacuum action draws fluids from the surgical site into the sealed liner — which is then safely removed and disposed of without spillage or contamination risk.

Set Up
1

Connect the antimicrobial Bacticlear® tubing to the vacuum source and to the mount canister T junction.

2

Insert the folded liner in the canister — match liner/canister sizes (never mix sizes). Connect the vacuum tapered connector. Check for perfect sealing of the sample port.

3

Switch on the vacuum controller to its maximum setting to ensure the liner unfolds correctly and to verify the effectiveness of the vacuum action.

4

Connect the patient tubing to the elbow (remove the elbow when using wide bore tubing).

5

Proceed with the suction. Once the fluid reaches its maximum level, the overflow hydrophobic valve will automatically cease the suction process.

Safe Disposal
1

Carefully detach the patient tubing from the liner.

2

Close the patient port using the patient port plug to fully seal the liner contents.

3

Switch off the vacuum.

4

Disconnect the vacuum tapered connector from the liner.

5

Grasp the side handles of the liner firmly.

6

Lift and extract the liner from the canister. The used liner and its contents can be safely transported for disposal.

Order Now — Available in Ghana

Request a Quotation for VacSax FluidGuard Flexi

Available now in Ghana through The Endoscopy People. Contact us with your canister type preference, liner size and estimated monthly volume and we will respond with pricing within 24 hours.